Peristaltic Pump with FVS
(Flow Verification
System)
|

|
Note: A diaphragm pump requires the
sensor to be mounted on the discharge (output) side of the pump
head. |
Installing the FVS Flow
Monitor | |
-
The Flow Verification Sensor (FVS)
should be installed on the inlet (suction) side of the pump tube.
The sensor includes a PVC tubing insert, located inside the
sensor's female thread connection, that is designed to seal the
sensor onto the pump tube inlet adapter.
-
Thread the sensor onto the pump tube
until the tubing insert is snug against the pump tube inlet
fitting. Do not over tighten.
-
Connect the RED, BLACK, and WHITE wires
from the sensor to the RED, BLACK, and YELLOW wires located in the
pump's junction box. |
|
Caution:
Always wear protective
clothing, face shield, safety glasses and gloves when working
on or near your metering pump. Additional precautions
should be taken depending on the solution being pumped. Refer
to MSDS precautions from your solution
supplier. |
|
Note:
All diagrams are strictly for
guideline purposes only. Always consult an expert before
installing the metering pump on
specialized systems. The metering pump
should be serviced by qualified persons
only. | |
|