DC AMPS AND AMP / HR, CONTROLLER TEXMATE
The customer has an application that requires to:
• Display Amps from a DC shunt. • Display and control from dual totalized amp/hrs. The amp/hrs from totalizer 1 operate Setpoint 1. At programmed amp/hr intervals, a pump starts for a programmed On-time to pump replenishment chemicals to the plating tank. When Setpoint 1 energizes, totalizer 1 resets to 0, the pump cycle starts, and the amp/hrs totalizer 1 restarts.
The amp/hrs from totalizer 2 operates Setpoint 2.
The chemical has a total life cycle calculated in DC amp/hrs, Setpoint 2 operates an alarm advising the operator when the chemical life has been exceeded. When the chemical is changed a reset button is pressed and totalizers1 and 2 are reset to 0.
APPLICATION VARIATIONS
|
|